Adams Rite PS-EXIT Power Supply for 8000 and 3000 Series MLR or LR Exit Devices
Adams Rite PS-EXIT Power Supply for 8000 and 3000 Series MLR or LR Exit Devices

Adams Rite PS-EXIT Power Supply for 8000 and 3000 Series MLR or LR Exit Devices
PS-EXIT | R8-PSEXIT
Please sign in to view pricing and availability and to add to cart.
Product Overview
The PS-EXIT Power Supply is specifically designed to protect and optimize the performance of Adams Rite 8000/3000 Series exit devices with Motorized Latch Retraction (MLR) or Electric Latch Retraction (LR) options by delivering filtered and regulated power.
Function:
This power supply is designed to provide power and control for up to two MLR or LR exit devices. Each exit device is controlled by a timer that is initiated by a switch closure. The timer is user-configured and holds the exit device(s) in the unlatched position for 2 - 60 seconds. At the end of the selected time, the exit device(s) will re-latch. If the switch controlling the exit device is closed longer than the selected time, the exit device remains unlatched until the controlling switch is released.
- An optional mode is available that allows both retraction timers to activate in response to a closure of either switch.
- Exit devices under access system control remain latched during a complete power failure but always allow free mechanical egress
Features:
Housing: Hinged, steel cabinet measures 10" x10-3/8" x 4-1/8" [254 mm x 263.5 mm x104.8 mm]. Blue, baked enamel finish with knockouts for conduit connections. Sized to accommodate two sealed, lead acid batteries (7AH, not included).
Timer: Initiated by switch closure to control each exit device. Timer is user-configured and holds exit device in unlatched position for 2 - 60 seconds. At end of selected time, exit device will relatch.
Operating Modes: The PS-EXIT is designed to power up to two 8000/3000 MLR or LR exit devices in the following operating modes:
- Single Input (Sequential Operation): either input retracts the corresponding exit device followed by retraction of second device. Control double-door exit with one input.
- Dual Input (Independent Operation): Each exit device is controlled by its own input switch. Control two separate exits with two inputs.
Main Features
- Converts current to the desired voltage and frequency to manage your power requirements
- The compatible output voltage of 24V DC ensures that the device is ready to use when needed
- Certifications: UL 294, CAN/CSA-C22.2 No. 223
- Input Power: 115 VAC
- Rated Output Current: Up to 0.8A per channel continuous rated output current
- Typical Output Voltage:24 - 26 VDC, Up to 17 A pull-in current
General Information
Specifications
ADI Part Number R8-PSEXIT Brand Name Adams Rite by ASSA ABLOY Manufacturer ASSA ABLOY Manufacturer Part Number PS-EXIT Packaged Quantity 1 Product Model PS-EXIT Product Name PS-Exit Exit Device Power Supply Product Series PS Product Type Power Supply Sector Access Control
Output Voltage 24V DC, 26V DC
Color Blue Depth 10.4" Form Factor Enclosure Height 10" Width 10.4"
Input Voltage 120V AC Output Current 17A
Limited Warranty 5-Year
Compatibility Adams Rite Exit Devices: - 8000 Motorized Latch Retraction
- 8000 Electric Latch Retraction
- 3000 Motorized Latch Retraction
- 3000 Electric Latch Retraction
Country of Origin US Environmental Certification UL Environmentally Friendly Yes